Your Leading EDI Equipment Supplier
Qingzhou Foren Water Treatment Equipment Co., Ltd. is a professional manufacturer specializing in the research and development (R&D), production, and sales of water treatment and filling equipment. Our main products include a wide variety of water treatment equipment, such as reverse osmosis systems, UF system/NF systems, EDI equipment, water softener systems, wastewater recycling systems, containerized water treatment systems, seawater desalination plants, and water treatment equipment accessories, providing integrated solutions for the water treatment, industrial water treatment, beverage, and pharmaceutical industries.
-
RO EDI SystemThe RO EDI system, based on reverse osmosis (RO) technology and combined with electro-deionization (EDI) deep purification, achieves a dual enhancement in water quality, ultimately producing...view more
-
Electrodeionization EDI SystemThe electrodeionization EDI system is a professional water treatment unit tailored for deep water purification and desalination.view more
-
EDI Water Purification SystemOur EDI water purification system is built with a proven modular layout, professionally configured with membrane stacks and ion exchange resin to deliver a complete one-stop water purification...view more
-
EDI Water Treatment SystemFor factories and production facilities in need of steady ultra-pure water supply, professional EDI water treatment system has become the most practical and cost-effective solution available.view more
-
Electrodeionization SystemElectrodeionization systems remove ions from aqueous solutions, sustainably producing ultrapure water. Reverse osmosis with electrodeionization (EDI) is an environmentally friendly deionized water...view more
Why Choose Us?
Integrated Solution Capability
We provide end-to-end solutions covering system design, equipment supply, installation, and after-sales service, helping customers streamline project execution.
Proven Industry Experience
We have established long-term cooperation with domestic and international clients, supported by extensive project experience in water treatment and filling systems.
Reliable Product Performance
Our systems are designed for stable operation, energy efficiency, and easy maintenance, ensuring long-term and cost-effective use in various industries.
Quality Assurance and Compliance
We operate under ISO 9001 standards, with strict testing and inspection processes to ensure consistent quality and reliable performance.
Specifications of EDI Equipment
|
Item |
Specification |
|
Product Name |
EDI Equipment (Electrodeionization System) |
|
Application |
High purity water production |
|
Feed Water Requirement |
RO permeate water |
|
Product Water Resistivity |
Up to 18 MΩ·cm |
|
Silica Removal Rate |
≥ 99% |
|
Conductivity Reduction |
Continuous ion removal |
|
Recovery Rate |
90–95% |
|
Operating Mode |
Continuous operation |
|
Chemical Consumption |
No acid or caustic regeneration required |
|
Power Supply |
AC 380V / 50Hz |
|
Flow Capacity |
Customized from small to large industrial systems |
|
Module Type |
Standard EDI modules |
|
Control System |
PLC automatic control |
|
Monitoring Parameters |
Conductivity, resistivity, pressure, flow rate |
|
Material of Piping |
UPVC / SS304 / SS316 |
|
Installation Type |
Skid-mounted design |
|
Industries Served |
Power plant, pharmaceutical, electronics, semiconductor, laboratory, food & beverage |
|
Maintenance Requirement |
Low maintenance |
|
System Integration |
Compatible with RO systems |
|
Water Quality Standard |
Suitable for ultrapure water applications |

Capable of continuous production of high-purity purified water
It is capable of continuous production of purified water with a specific resistivity of 10 MΩ·cm or higher.
No need for regeneration chemicals
Because it is electrically regenerated, no regeneration chemicals are required.
It is capable of reducing running costs compared to conventional ion exchange methods.
Easy operation management and maintenance
Operation control is easy as there is no regeneration operation with chemicals.
Space-saving
Because of its unit design, it can be installed in a space-saving manner.
Workflow of EDI Equipment
Introduction of feed water. Pretreated water enters the system and passes through an initial treatment stage where larger contaminants and particles are extracted.
Ion exchange procedure. As the feed water flows through the resin beds, positive ions are substituted for hydrogen ions (H+) and negative ions for hydroxide ions (OH-). This initiates the deionization of the water, though it does not achieve total purification independently.
Electrochemical reaction. Upon the application of power to the electrodes, H+ and OH- ions are compelled towards their respective electrodes due to the electric field created. This movement boosts ion removal efficacy, continually regenerating the ion exchange sites within the resin beds.
Removal of concentration stream. The concentrated stream consisting of extracted impurities is drained through a separate outlet while the purified deionized water is output as the end product.
Continuous operation. Unlike conventional deionization techniques that necessitate intermittent regeneration with chemicals, EDI systems maintain a constant operation without the need for chemical regeneration, making them more proficient and environmentally considerate.
Customization Options
|
Quality requirements |
Optional |
|
Pipe material |
Optional |
|
MOQ |
Customizable |
Maintenance of EDI Equipment
1. Maintain accurate operational records, carefully observing and recording the technical parameters of each node.
2. Although most equipment uses fully automatic intelligent control, regular inspections are still necessary.
3. Pay close attention to pretreatment equipment, regularly checking if the automatic cleaning system is functioning correctly and ensuring the effluent water quality meets standards (focusing on contamination index and ORP index).
4. Replace precision filter cartridges regularly; replace them promptly when the inner layer of the filter cartridge turns gray.
5. Continuously monitor the pressure, flow rate, and water quality indicators of the reverse osmosis unit during operation. Analyze and resolve any abnormalities promptly, and perform chemical cleaning when necessary.
6. For the EDI precision electro-deionization unit, pay attention to the technical parameters such as permeable water quality, inlet and outlet pressures for desalinated and concentrated water, operating voltage, and current. Regenerate and perform chemical cleaning promptly based on changes in these parameters.
7. For polishing resin filters, pay attention to the inlet water quality during daily management. Water that does not meet design requirements should not be introduced, otherwise it will fail too quickly.
8. Adhere to the principle that "if the effluent water quality of each treatment unit is not up to standard, it cannot enter the next treatment unit." Otherwise, it will increase the processing load of the next unit and cause irreversible damage.
Methods For Adjusting PH In EDI Equipment
To make sure EDI works well and lasts a long time, it's important to keep the pH levels in the feedwater just right. Here are some ways to adjust the pH:

Check that the pH of the feedwater is between 5.5 and 7.5, which is the right range.

Use automatic pH control devices to keep everything in check all the time.

When you need to change the pH, use acids or bases that are safe for food.
Payment Terms
T.T with 30% downpayment, 70%before shipment. Paypal or West Union also accept.
Packing & Transportation
|
Category |
Details |
|
Packaging Method |
Container loading;protective film wrapping; wooden crates; reinforced with steel bars. |
|
Transportation Method |
Sea freight (preferred for large items); |
|
Air freight (for emergency spare parts). |
FAQ
As one of the most professional edi equipment manufacturers and suppliers in China, we offer a wide range of products with superior quality. Please feel free to buy customized edi equipment made in China here from our factory. Contact us for quotation.
di water treatment, RO EDI, edi in ro plant